<LOGO>
FM Transmitter Measurement Report
Created: 2025-10-15 08-12-13
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
101.90 MHz 5/5, 47 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz 3.2 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
6 kHz 15 kHz 11184 0,0805
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-0,9 dBr -0,28 dBr 0,3 dBr 0,2
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 8:12, 15.10.2025
RT
"Ranni Plus - Politika, spolecnost, byznys, veda. Moderuji Pav..."
AF EON
91.3, 91.5, 92.6, 92.8, 93.3, 93.5, 93.9, 94.1, 95.4, 97.8, 100.8, 101.5, 101.9, 103.6, 107.2 MHz -
FM Scope Max at: 15 kHz MIN: 6 kHz % above 77 kHz: 0,0805 Acquired: 2025/10/15 8:12:10 Total samples: 11184 Equivalent time: 0:09:19 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400